Application:
This series is widely used for Izod and Charpy impact test on plastics and plastic pipes. Equipped with tensile impact pendulum and fixtures, it can carry on tests on plastic film and sheet.
Standards
ISO 179, ISO 180, ISO 8256, ISO 9854.1, ASTM D256, ASTM D1822,ASTM D6110
Specifications
Type | Charpy | Izod | |
Maximum impact energy | To be confirmed according to the Pendulum | 22J | |
Impact energy (ISO, GB) | 4J、 | 7.5J,15J,25J,50J | 5.5J,11J,22J |
Impact Energy (ASTM) | - | 5.4J、10.8J、21.6J | |
Impact velocity | 2.9m/s | 3.8 m/s(ISO、GB) | 3.5 m/s(ISO、GB) |
3.46m/s(ASTM) | |||
The distance from the center of the pendulum axis to the center of the specimen | 395mm(ISO、GB) | 335mm | |
Radius of blade fillet | R=2mm | R=0.8mm | |
Blade Angle | 30º | 75º | |
Pendulum prelift Angle | 95.5° | 150° | 150°(ISO、GB)、145.2°(ASTM) |
Support fillet radius | R=1mm | R=0.2 | |
Front Angle of support | 5 º | -------- | |
Back Angle of support | 10 º | -------- | |
Support span | 40mm、60mm、62mm、70mm | -------- | |
Sample type and size (length × width × thickness) mm3 | ISO179-2000 | ISO180-2000、 | |
Type 1 sample:80×10×4 | GB/T 1843-1996: | ||
GB/T 1043-2008: | Type 1 sample:80×10×4 | ||
Type 1 sample:80×10×4 | Type 2 sample 63.5×12.7×12.7 | ||
Type 2 sample:50×6×4 | Type 3 sample:63.5×12.7×6.4 | ||
Type 3 sample:120×15×10 | Type 4 sample:63.5×12.7×3.2 | ||
Low temperature environment | Room temperature~ - 70℃ | ||
Angular resolution | 0.045° | ||
Energy resolution | Better than 1/2375FS | ||
Power source | AC 220V 50Hz |
Sie können mich auch per E-Mail kontaktieren. Meine E-Mail-Adresse ist admin@hssdtest.com